nice and renice

$
0
0
hello ,

We would like to increase the priority of the oracle process . Process(240001 ) should get the priority like the process(240103 ). Am not sure what value i should mention in the renice command(aix 6.1). Please assist me.

Code:

 
  240001 A  oracle 26804312        1  0  60 20 89fd69590 171720            Jul 19      -  0:27 ora_dbrm_wbubst1


240103 A  oracle  8650850        1  0  39 -- 8a6b6f590 193436            Jul 19      -  0:13 ora_lgwr_wbubst1

Thanks,
Gowtham.G

HACMP

$
0
0
Does anyone has idea about, what is the ibm standard HACMP trip interval?

We have 20 second.

Code:

lssrc -ls topsvcs
Subsystem        Group            PID    Status
 topsvcs          topsvcs          1843200 active
Network Name  Indx Defd  Mbrs  St  Adapter ID      Group ID
HB Interval = 1.000 secs. Sensitivity = 10 missed beats
Missed HBs: Total: 3 Current group: 0
Packets sent    : 2595710 ICMP 0 Errors: 0 No mbuf: 0
Packets received: 3364963 ICMP 0 Dropped: 0
NIM's PID: 1781806
HB Interval = 2.000 secs. Sensitivity = 5 missed beats
Missed HBs: Total: 0 Current group: 0
Packets sent    : 774925 ICMP 0 Errors: 0 No mbuf: 0
Packets received: 774962 ICMP 0 Dropped: 0
NIM's PID: 1908932
  2 locally connected Clients with PIDs:
haemd(1961990) hagsd(684036)
  Fast Failure Detection available but off.
  Dead Man Switch Enabled:
    reset interval = 1 seconds
    trip  interval = 20 seconds
  Client Heartbeating Disabled.
  Configuration Instance = 263
  Daemon employs no security
  Segments pinned: Text Data.
  Text segment size: 900 KB. Static data segment size: 1493 KB.
  Dynamic data segment size: 5249. Number of outstanding malloc: 158
  User time 135 sec. System time 152 sec.
  Number of page faults: 182. Process swapped out 0 times.
  Number of nodes up: 2. Number of nodes down: 0.

Help with virtual optical device

$
0
0
Hi

My P6 server is with dual vio servers. From the below output we could see that cd devices(cd0 and cd1) has been mapped to the vio client named prdsapfi1.

When we execute "lsdev -Cc cdrom" in prdsapfi1 there are 2 cd devices named cd0 and cd1 showing up in available state.

Code:


===========================================================================
prdsapfi1:/ # lsdev -Cc cdrom
cd0 Available  Virtual SCSI Optical Served by VIO Server
cd1 Available  Virtual SCSI Optical Served by VIO Server
===========================================================================

My question is how to find out if cd0 showing up in prdsapfi1 has been coming from vioprd01p or vioprd01i?

Code:


===========================================================================
$ hostname
vioprd01p
===========================================================================
$ lsvopt | grep -i prdsapfi1
prdsapfi1_cdrom    No Media                                    n/a
===========================================================================
$ oem_setup_env
===========================================================================
# lsdev -Cc cdrom
cd1 Defined 05-08-01-0,0 16 Bit LVD SCSI DVD-RAM Drive
===========================================================================


Code:

===========================================================================
$ hostname
vioprd01i
===========================================================================
$ lsvopt | grep -i prdsapfi1
prdsapfi1_cdrom    AIX61.iso                              3967
===========================================================================
$ oem_setup_env
===========================================================================
# lsdev -Cc cdrom
cd0 Available 0F-08-00    SATA DVD-ROM Drive
cd1 Defined  05-08-01-0,0 16 Bit LVD SCSI DVD-RAM Drive
===========================================================================

New to AIX

$
0
0
Hi,

I was working with hp-ux for 2+ years.

I am new to AIX. So, Please help me in learning AIX. Pls share the study guides or ppts which would help me understand the basics of AIX.

Thanks,
Vidhya.

AIX How to run a Shell Script by changing the User

$
0
0
Hi All,

Currently our application is running on the server having AIX 5.3 OS.

What we intend to do is to run a shell script owned by another user and needs to be run as that particular user.

I was trying to create a shell script using the su command before running the actual script (which will be executed from the new script). The su command always prompt for a password. Is there any way we can put that in the shell script so that there is no user prompt.

Also please guide if there is any better methodologies to achieve this.

Thanks

Abhik

last - find out inactivity

$
0
0
I am on AIX 6.1, and need to find out who has not accessed the system within 1, 2, or 3 months depending upon the filter I specify.

The output I need to have is the account name and the last time accessed:

i.e.

kart Mar 27 05:13 - 05:13 (00:00)

Please advise.

Not able to redirect output of command

$
0
0
Hi All,.
We are using AIX as the OS to host the Oracle ERP. We have a command FNDLOAD which is used to load setups. When this command is run, it outputs names of log files and any errors to the screen.

I am trying to redirect this output to a file because we have large number of these commands running from a script and would like to log them.

I can redirect normal echo commands to a file without a problem, but the output of this command is not getting redirected.

I tried >, >>, |, | tee till now. None of it works. Any solution?

[Solved] how to Enable VxDMP & Disable MPIO?

$
0
0
Hello people.
I am new to AIX & dealing with VxDMP.

The server has AIX 7.1, storage is Hitachi. I have 4 paths from my server to the array. However, the vxdmp shows only single path. I went through some discussions & realized that it is because of MPIO.

Then,
I did following -

* Uninstalled Vx Stack
* Removed disks using rmdev -dl disk
* Installed the Object Data Manager (ODM) definitions for the devices on the host. (Hitachi)
* Reboot server
* Re-Install Vx

Still no avail! Only single path is seen.
Am I missing something?

---------- Post updated at 05:01 AM ---------- Previous update was at 03:23 AM ----------

We nailed it!

Some mistake on my part.

>> Installed the Object Data Manager (ODM) definitions for the devices on the host. (Hitachi)

Apparently, I had installed "MPIO ODM" instead of "non-MPIO ODM's"

Uninstalling the MPIO ODM & installing non-MPIO ODMs (followed by cfgmgr) solved the issue.

Moderator's Comments:
edit by bakunin: many thanks for writing this follow-up and glad you found it. Thread title changed to "Solved".

Can only ls 50 file on NFS mount?

$
0
0
Please can anybody help me with this weird behaviour.

There are 2 x-servers running Fedora 16 work as a cluster with DRBD, corosync & pacemaker. The cluster exports a filesystem using the following statement in /etc/exports
Code:

/drbd/home      10.49.17.0/255.255.255.0 fsid=1,rw,no_root_squash,no_acl,mountpoint)
This directory is then NFS mounted on various machines using automount.
The problem is that on 2 AIX machines running 32bit 5.2 & 5.3 whichever user, even root, does an ls on the mounted directory the error message "ls: out of memory" is returned when there are more than 50 files.
This problem does not occur on machines running Fedora 16, 64bit AIX5.3 or even a very old machine running AIX3.2.5.

The same automount event is used on all the AIX5 machine whether 32 or 64 bit.
Code:

/home/ANS      -rw,bg,soft,sec=sys,noacl,ver=3 nfssv:/drbd/home
Any ideas would gratefully received.

Moderator's Comments:
edit by bakunin: Please use [CODE]..[/CODE]-tags not only for code but also for file content, terminal ouptut and the like. Thank you.


---------- Post updated at 03:07 PM ---------- Previous update was at 10:23 AM ----------

So if I do the NFS mount as version 2 on the 2 problem machines, then there isn't a 50 file limit.

SNMPv3 error - Help please!

$
0
0
Hello everyone:
I'm still relatively new to AIX administration and learning every day. I need to configure SNMPv3 in several servers. I tried first on a "test environment" server, no firewalls, and I was successful.
Then I moved on to the "production" servers, which are behind firewall and I can't make SNMPv3 work! I checked the firewall and the ports 161 and 162 are open and traffic is allowed.
The settings are exactly the sme in both environments.
This is an example of what I get in the production servers:

Code:

> clsnmp -h user1 walk system
clsnmp: 1473-402 Error return from SnmpRecvMsg().

When I run the same command in debug mode, I get this error:

Code:

P1: wsnmp_com.c( 128): Call session callback, request 1 (1 app), error 199
P1: clsnmp.c(1283): In HandleSnmpResponse()
P1: clsnmp.c(1291): calling SnmpRecvMsg with SessionHandle 1
P1: wsnmp_com.c(1902): In SnmpRecvMsg for session 1
E3: wsnmp_com.c(1920): Global global_error_code set to 199 (><SNMPAPI_TL_OTHER - Undefined transport layer error.)
E3: wsnmp_com.c(1920): Session 1 local error_code set to 199 (><SNMPAPI_TL_OTHER - Undefined transport layer error.)

Any ideas? I've been trying to figure this out for two days with no success! :wall:

Thank you.

Moderator's Comments:
Please use code tags next time for your code and data.

Connected and Running with half duplex speed

$
0
0
VIO Server connected to switch port and running with half duplex speed on one of the shared ethernet adapter. We have verified at switch end and everythings looks good.
Other ethernet adapter in the VIO server are connected and running in Full duplex speed.

Please help me find why this shared ethernet adapter is having half duplex speed and how to fix this back to full duplex.

Sometime back it was running as full duplex and recently there were no changes/upgrades on both switch and VIO server level.

Code:


$ ioslevel
2.1.2.10-FP-22
 
# lsdev -Cc adapter | grep -i ent14
ent14    Available      Shared Ethernet Adapter
 
# entstat -d ent14 | grep -i media
Media Speed Selected: Auto negotiation
Media Speed Running: 10 Mbps Half Duplex
 
# lsattr -El ent14 | grep -i real
real_adapter  ent4    Physical adapter associated with the SEA                          True

- Mugunth

Internal PCI X RAID Controller issue ?

$
0
0
Hello folks,

Could someone tell me why I unable to create pdisks for a RAID Array

Code:


# lscfg | grep scsi
+ sisscsia0        U787A.001.DPM0707-P1            PCI-X Dual Channel Ultra320 SCSI Adapter
+ scsi0            U787A.001.DPM0707-P1-T10        PCI-X Dual Channel Ultra320 SCSI Adapter bus
+ scsi1            U787A.001.DPM0707-P1-T11        PCI-X Dual Channel Ultra320 SCSI Adapter bus

Code:

smitty devices

Move cursor to desired item and press Enter.

  RAIDiant Disk Array
  IBM PCI SCSI Disk Array
 > IBM PCI-X SCSI Disk Array
  FC SCSI RAIDiant Disk Array

I will select PCI-X SCSI Disk Array

then

Code:


Move cursor to desired item and press Enter.

  PCI-X SCSI Disk Array Manager
  Configure a Defined PCI-X SCSI RAID Controller
  Unconfigure an Available PCI-X SCSI RAID Controller
  Change/Show PCI-X SCSI RAID Controller Bus
  Download Microcode to a PCI-X SCSI RAID Controller

when I click on Configure a defined PCI-X SCSI RAID Controller
or on Change/Show PCI-X SCSI RAID Controller Bus
I get
Code:

ERROR MESSAGE                              │
            │                                                                          │
            │ Press Enter or Cancel to return to the                                  │
            │ application.                                                            │
            │                                                                          │
            │  1800-051 There are no items of this type.


what could be the issue ?

Filesystem using Oracle and mirroring VG ?

$
0
0
Hello,

I have a filesystem which has Oracle EBS 11.5.9 running and database 9i


Code:

# df -g

Filesystem    GB blocks      Free %Used    Iused %Iused Mounted on

/dev/fslv00      270.00    69.68  75%  746263    5% /oratec

which is in oraclevg

# lsvg oraclevg
VOLUME GROUP:      oraclevg                VG IDENTIFIER:  00c82b6e00004c0000000133f8a8c64c
VG STATE:          active                  PP SIZE:        256 megabyte(s)
VG PERMISSION:      read/write              TOTAL PPs:      1092 (279552 megabytes)
MAX LVs:            256                      FREE PPs:      11 (2816 megabytes)
LVs:                2                        USED PPs:      1081 (276736 megabytes)
OPEN LVs:          2                        QUORUM:        2
TOTAL PVs:          2                        VG DESCRIPTORS: 3
STALE PVs:          0                        STALE PPs:      0
ACTIVE PVs:        2                        AUTO ON:        yes
MAX PPs per VG:    32512                                    0
MAX PPs per PV:    1016                    MAX PVs:        32
LTG size (Dynamic): 256 kilobyte(s)          AUTO SYNC:      no
HOT SPARE:          no                      BB POLICY:      relocatable


Now if I mirror oraclevg, will the oracle EBS run slow after mirroring of oraclevg ?

multibos - can I remove hd5 if booted from bos_hd5

$
0
0
Hi,

I'd like to know - can I simply remove all the standard OS lvs - ie hd2, hd5, hd9var, hd10opt hd4, while the system is running on multibos bos_ lv's, and then re-run multibos to re-create the standard lvs?


I'm having an odd problem with a multibos installation.
The system is currently running on the bos_hd5.
I'd like to do a new multibos clone prior to doing an OS update, but multibos won't let me, saying "Maximum number of standby BOS installations already exist".

multibos -R also exits with the following errors:

multibos: 0565-080 Error reading LVCB attribute "fs,mb" of logical volume
bos_hd5.
multibos: 0565-082 Unable to verify multibos tag for standby BOS logical volume
bos_hd5
multibos: 0565-084 Error processing primary boot partition.
multibos: 0565-002 ATTENTION: cleanup did not complete successfully.


I would just reboot back to the other "standard" hd5 image, and start again from there, but it appears that hd4 is missing, so I'd expect a reboot to that image will fail.

So, can I simply remove all the standard OS lvs - ie hd2, hd5, hd9var, hd10opt (and hd4 if it was there), while the system is running on the bos_ lv's, and then re-run multibos?

Will this default to re-creating the standard lvs from the current bos_ lvs?

Are the bos_ lvs and the standard lvs truly equivalent? Or do I risk losing some vital information by doing this?

TIA, Alan.

VIO Server

$
0
0
Hi,

I am facing an issue in vio server. When I run
Code:

bosboot -ad /dev/hdisk0
I am getting an error
Code:

trustchk: Verification of attributes failed: /usr/sbin/bootinfo
: accessauths

regards,

vjm

Moderator's Comments:
Please use code tags next time for your code and data.

[Solved] Configure VIOS SEA w. load sharing

$
0
0
I am trying to install a VIOS pair with a load-sharing SEA adapter, following this recipe from Developerworks. Without load-sharing everything went fine and worked as expected, but somehow i am a bit lost and the first tries with "ha_mode=sharing" didn't work at all.

Here is the situation:

I have one VIOS pair and in each VIOS i have one SEA contructed from 2 physical Ethernet Adapters (10G-Ethernet). The adapters (ent0 and ent1) as well as the SEA (ent2) work testedly well, as did the control-channel.

From the "outside" i have several VLAN IDs, "internal" i have only one (which might change, we build the machine right now).

What i tried to achieve was to have the SEA of the second VIOS share the load instead of having an idle stand-by. I wanted to base the load-sharing on the external VLAN IDs (VIOS 1 serving ext. VLANs A, C, E, ... and VIOS 2 serving ext. VLANs B, D, F, ...). For this i created one virtual adapter for each external VLAN on the SEA and tried to switch on load-sharing, but got no communication.

I suspect that i somehow missed the proper VLAN layout and confused internal and external VLANs somehow in my HMC definitions. Maybe someone has already done that and can shed some light on this. Some step-by-step how-to would be appreciated.

Another question is: how do i create additional internal VLANs and put them on this setup? Right now there is no need for additional VLANs but this requirement might well change over time.

Thanks for your help.

bakunin

VIO and LPAR disk/fcs communications

$
0
0
:wall::wall::wall:

1. I have created an LPAR in the HMC.
2. I have allocated the storage from an Hitachi AMS2500 and assigned it to the host group.
3. I have zoned the LPAR and Storage on a Brocade 5100. (The zone sees the AMS)

Next I activated the LPAR in the HMC, SMS mode for the mksysb load.
It gets to this point in the Terminal and hangs. (text is not an exact replica)
(See Attachment)
Code:

-------------------------------------------
Welcome to AIX
Boot image timestamp
Current time and date
Processor count - etc
boot device - etc
----------------------------------------------

VIO shows the following: (vfchost15 is the one I am working on)

Code:

padmin@vio7 $ lsdev -slots
# Slot                      Description      Device(s)
U8202.E4B.1047F6P-V1-C0      Virtual I/O Slot  vsa0
U8202.E4B.1047F6P-V1-C2      Virtual I/O Slot  ent4
U8202.E4B.1047F6P-V1-C3      Virtual I/O Slot  ent5
U8202.E4B.1047F6P-V1-C5      Virtual I/O Slot  vfchost1
U8202.E4B.1047F6P-V1-C6      Virtual I/O Slot  vfchost2
U8202.E4B.1047F6P-V1-C7      Virtual I/O Slot  vfchost4
U8202.E4B.1047F6P-V1-C8      Virtual I/O Slot  vfchost3
U8202.E4B.1047F6P-V1-C9      Virtual I/O Slot  vfchost5
U8202.E4B.1047F6P-V1-C10    Virtual I/O Slot  vfchost12
U8202.E4B.1047F6P-V1-C11    Virtual I/O Slot  vfchost6
U8202.E4B.1047F6P-V1-C12    Virtual I/O Slot  vfchost0
U8202.E4B.1047F6P-V1-C13    Virtual I/O Slot  vfchost7
U8202.E4B.1047F6P-V1-C14    Virtual I/O Slot  vfchost8
U8202.E4B.1047F6P-V1-C15    Virtual I/O Slot  vfchost9
U8202.E4B.1047F6P-V1-C16    Virtual I/O Slot  vfchost10
U8202.E4B.1047F6P-V1-C17    Virtual I/O Slot  vfchost11
U8202.E4B.1047F6P-V1-C18    Virtual I/O Slot  vfchost13
U8202.E4B.1047F6P-V1-C19    Virtual I/O Slot  vfchost14
U8202.E4B.1047F6P-V1-C20    Virtual I/O Slot  vfchost15
U8202.E4B.1047F6P-V1-C32769  Virtual I/O Slot  vasi0
padmin@vio7 $

I have tried removing and re-configuring the vfchost15. (Commands Below)

Code:

padmin@vio7 $ rmdev -pdev vfchost15
padmin@vio7 $ rmdev -dev vfchost15
vfchost15 deleted
padmin@vio7 $ lsdev -slots
# Slot                      Description      Device(s)
U8202.E4B.1047F6P-V1-C0      Virtual I/O Slot  vsa0
U8202.E4B.1047F6P-V1-C2      Virtual I/O Slot  ent4
U8202.E4B.1047F6P-V1-C3      Virtual I/O Slot  ent5
U8202.E4B.1047F6P-V1-C5      Virtual I/O Slot  vfchost1
U8202.E4B.1047F6P-V1-C6      Virtual I/O Slot  vfchost2
U8202.E4B.1047F6P-V1-C7      Virtual I/O Slot  vfchost4
U8202.E4B.1047F6P-V1-C8      Virtual I/O Slot  vfchost3
U8202.E4B.1047F6P-V1-C9      Virtual I/O Slot  vfchost5
U8202.E4B.1047F6P-V1-C10    Virtual I/O Slot  vfchost12
U8202.E4B.1047F6P-V1-C11    Virtual I/O Slot  vfchost6
U8202.E4B.1047F6P-V1-C12    Virtual I/O Slot  vfchost0
U8202.E4B.1047F6P-V1-C13    Virtual I/O Slot  vfchost7
U8202.E4B.1047F6P-V1-C14    Virtual I/O Slot  vfchost8
U8202.E4B.1047F6P-V1-C15    Virtual I/O Slot  vfchost9
U8202.E4B.1047F6P-V1-C16    Virtual I/O Slot  vfchost10
U8202.E4B.1047F6P-V1-C17    Virtual I/O Slot  vfchost11
U8202.E4B.1047F6P-V1-C18    Virtual I/O Slot  vfchost13
U8202.E4B.1047F6P-V1-C19    Virtual I/O Slot  vfchost14
U8202.E4B.1047F6P-V1-C20    Virtual I/O Slot  Unknown
U8202.E4B.1047F6P-V1-C32769  Virtual I/O Slot  vasi0
padmin@vio7 $ cfgdev
padmin@vio7 $ lsdev -slots
# Slot                      Description      Device(s)
U8202.E4B.1047F6P-V1-C0      Virtual I/O Slot  vsa0
U8202.E4B.1047F6P-V1-C2      Virtual I/O Slot  ent4
U8202.E4B.1047F6P-V1-C3      Virtual I/O Slot  ent5
U8202.E4B.1047F6P-V1-C5      Virtual I/O Slot  vfchost1
U8202.E4B.1047F6P-V1-C6      Virtual I/O Slot  vfchost2
U8202.E4B.1047F6P-V1-C7      Virtual I/O Slot  vfchost4
U8202.E4B.1047F6P-V1-C8      Virtual I/O Slot  vfchost3
U8202.E4B.1047F6P-V1-C9      Virtual I/O Slot  vfchost5
U8202.E4B.1047F6P-V1-C10    Virtual I/O Slot  vfchost12
U8202.E4B.1047F6P-V1-C11    Virtual I/O Slot  vfchost6
U8202.E4B.1047F6P-V1-C12    Virtual I/O Slot  vfchost0
U8202.E4B.1047F6P-V1-C13    Virtual I/O Slot  vfchost7
U8202.E4B.1047F6P-V1-C14    Virtual I/O Slot  vfchost8
U8202.E4B.1047F6P-V1-C15    Virtual I/O Slot  vfchost9
U8202.E4B.1047F6P-V1-C16    Virtual I/O Slot  vfchost10
U8202.E4B.1047F6P-V1-C17    Virtual I/O Slot  vfchost11
U8202.E4B.1047F6P-V1-C18    Virtual I/O Slot  vfchost13
U8202.E4B.1047F6P-V1-C19    Virtual I/O Slot  vfchost14
U8202.E4B.1047F6P-V1-C20    Virtual I/O Slot  vfchost15
U8202.E4B.1047F6P-V1-C32769  Virtual I/O Slot  vasi0
padmin@vio7 $ vfcmap -vadapter vfchost15 -fcp fcs0
padmin@vio7 $ lsmap -vadapter vfchost15 -npiv
Name          Physloc                            ClntID ClntName      ClntOS
------------- ---------------------------------- ------ -------------- -------
vfchost15    U8202.E4B.1047F6P-V1-C20              18

Status:NOT_LOGGED_IN
FC name:fcs0                    FC loc code:U78AA.001.WZSG1DR-P1-C1-C3-T1
Ports logged in:0
Flags:4<NOT_LOGGED>
VFC client name:                VFC client DRC:

padmin@vio7 $

Then I re-activated the LPAR in SMS mode again with the same results.

I have triple checked the WWNs in the Storage and Zoning.
I have performed the above several times.
I don't know where I am going wrong as this is the procedure I have used many times before. I could use some trouble shooting help in regards to this issue.

Thanks


Moderator's Comments:
Please use code tags next time for your code and data.

Attached Files
File Type: doc gmussdbps LPAR Trouble.doc (59.0 KB)

AIX JFS2 content

$
0
0
Hello!

I have a LPAR with 51GB RAM

topas shows 21% of memory for client pages (~11Gb)
svmon -G show 2906772 client pages in use (~11Gb)

but then i try to investigate per process client memory usage
Code:

svmon -P -O filtertype=client
and summarize inuse column, i get only 347880 pages total(~1,3Gb)

there is difference or what did i do wrong?
Thanks in advice

Switch Port Becoming Private & restricting access

$
0
0
Hello folks,
I have an AIX server that is connected to a storage array via a Brocade switch using 4 ports from either side. The zoning is done such that there are 4 paths visible from the server to the storage.

My work involves frequent disabling or enabling the switch ports that are connected to the server. The switch ports connected to the server usually show status as "L Port Public". When I disable a port, the status for the corresponding port becomes disabled & the server starts seeing 3 paths. Everything as desired.

The issue is when I try to re-enable it. The port then shows the status as "L Port Private" & the server can not see that particular path to the storage in-spite of the port being enabled. Moreover, if I reboot the switch then all the 4 ports show status as " L Port Private"; leaving the server with zero access to the storage.

How do I make the disappeared path appear again?

This path appears again if I reboot both, the server & switch after enabling the port.

Error unmounting a remote mounted file system

$
0
0
Hi All,

I'm facing an issue while trying to unmount a remotely mounted file system, strangely it's not even getting mounted, Kindly find the reply messages.

Mounting error msg

nfsmnthelp: 1831-019 <Server host>: Cannot mount a file system that is already remotely mounted.
mount: 1831-008 giving up on:
Cannot mount a file system that is already remotely mounted.

Unmounting error msg

unmount: 0506-347 Cannot find anything to unmount.

If any one knows please help.